language: "en"
---
# iMC Dozer - As-Built

## *Source: D61EXi-24 Operation and Maintenance Manual P4-50*

As-built data is surface information collected by the intelligent machine after each pass of that particular surface.

## **As-Built Mode**

**Toggle****As-built**mode by selecting the shortcut icon shown:  
![image-20240729-001818.png](https://solutions.komatsu.com.au/__attachments/a_894cc6e64b379cbba619b67cfe52c318225a59de5552024658477d95dfccf067/image-20240729-001818.png?cb=022d7ac579fd81f9825b27127a25695b)  
Select desired view of As-built in **File \> Active \> AsBuilt**.

Three options are available:

1. **Cut Fill -**current terrain of the position where the machine passed is displayed by colour according to the cut/fill amount (distance) from the design surface. Allows operator to see where digging or raising ground level work is required.

2. **Pass Counts -**position where the machine passed is displayed by colour according to the number of times the machine has passed. Allows for checking the places and numbers of tamping.

3. **None**

![image-20240729-003115.png](https://solutions.komatsu.com.au/__attachments/a_1552de9b3c581dcfb797c82be2d90b727fc167b404def3f68c2a40258aef9960/image-20240729-003115.png?cb=dd3eb669e7c4a0e8c7399bc96ebab1f5)  

**Start**As-built surface updates by selecting the shortcut icon shown:  
![image-20240729-010436.png](https://solutions.komatsu.com.au/__attachments/a_12bed7e7fdd6137433484a9f0a954583d650e6d52c40a70239d0ba16c580372e/image-20240729-010436.png?cb=db51a54a6e9c7b1f7d476b36cd1b1e1f)  

**Stop**As-built surface updates by selecting the shortcut icon shown:  
![image-20240729-010645.png](https://solutions.komatsu.com.au/__attachments/a_b9cce100f590d4ad8fe9223b3e0e1c4ab4df80e4b288e7d52eb08399cab99ef7/image-20240729-010645.png?cb=70e74a686cdc1203fd5f52bdda60bde4)

### **Setting****As-built Control Options**

in **As-built control...** menu, As-built data settings can be configured.  
**Managed by Sitelink3D server**  
Control box will read the as-built data from the server  
**Local as-built only**  
Control box manages the as-built (internal memory). Addition/deletion of the locally managed as-built surface can be performed.

### **Adding****As-built Surface**

1. Press power ON/OFF to display the main menu

1. **Control** \> **As-built control...**

![image-20240815-045027.png](https://solutions.komatsu.com.au/__attachments/a_a9f5d234963861bdf1fa09f46dc0cba2028fd9970bd87cae68bd571512c52ab4/image-20240815-045027.png?cb=04d097fca7dac92c0645299c4f42dd87)  

2. In As-built control menu, ensure **Local as-built only**is selected

3. Select **\<new as-built layer\>** and **Ok**

![image-20240815-045212.png](https://solutions.komatsu.com.au/__attachments/a_1de487260ee833b4e883c4a5812d10d9c6960c66ad6af7b41600a8c2b4e4d1da/image-20240815-045212.png?cb=a4ad2c511def753424b2582a0f6c57a7)  

4. Enter layer name and cell size of the As-built surface and press **Ok**

![image-20240815-045254.png](https://solutions.komatsu.com.au/__attachments/a_cceebf87515090969204aa670c8cf8c1f25ac69859fcc1ebdee23fe94aa4f4af/image-20240815-045254.png?cb=68b189458d044a95764ecdb437d3b02c)